5.4 Installation of Electromagnetic Vibration Feeder

5.4.1 The allowable deviation for installation of electromagnetic vibration feeder shall be in accordance with those specified in Table 5.4.1.

Inspection quantity:exhaustive check.

Inspection method:see Table 5.4.1.

Table 5.4.1 Allowable deviation for installation of Electromagnetic Vibration Feeder

img

5.4.2 The air gap between the iron core and the armature iron shall be in accordance with the requirements specified in the design documents,and shall be less than 1mm in case no such requirements are available.

Inspection quantity:exhaustive check.

Inspection method:visual check,and checking with a feeler gauge.